Drop Down MenusCSS Drop Down MenuPure CSS Dropdown Menu
-->

Mother

Thursday 22 January 2015

Glauber Salt test

Glauber Salt test
Test process :
1.      First normal water hardness test. (Suppose 28 ppm.)
2.      Make 8% Glauber salt solution . Than test the solution hardness . (Suppose 36 ppm.)
3.      Than compare between water hardness and solution hardness.



Formula :

Glauber salt hardness = 8% Na2SO4 solution hardness – Water hardness.
 Such as : 36-28=8 ppm.




The salt is good.
If the salt hardness above 15ppm it will be not allowed.

Normally the salt hardness range is 4-15 ppm.

1 comment:

  1. Thank you for sharing such useful information. I really enjoyed while reading your article and it is good to know the latest updates. Do post more. And also read about

    Sodium Sulphate Suppliers

    ReplyDelete